Run production string, containing the appropriate seal Assemblies, into the well until the locator section of the Assembly seat on the bevelled top of the Packer body This is indicated by a weight decrease, or more reliably, with accurate measurements and application of pressure to the annulus. Once Locator Tubing Seal Assembly is located ,the calculated set down weight is applied.
NOTE : When sufficient set- down weight is not available, the use of an Anchor type Seal Assembly or additional Spacer seal Units, and Seal Bore or Seal Protector Extension is recommended.